Roof module distance, safety and performance

Manufacturers have installation manuals for their products with instructions and mechanical limits of the assemblies

There is a wide range of types of roofs where solar systems are usually installed, from residential ceramic roofs on roofs zipped metal of large warehouses. Naturally, many solutions will emerge fixing modules to roofs and which, given the specificity of each application, are not interchangeable.

As they are not interchangeable, situations may arise where the structure used is incompatible with the roof and with the module's ventilation and warranty requirements. In this article, we will study technically and commercially the implications of using structures that do not allow the minimum spacing between module and roof recommended by manufacturers.

Figure 1 – Typical structure for mounting on a ceramic roof. The elevation of the module in relation to the roof can be compatible with the requirements of the module installation manual
Figure 2 - Mini-rail type structures are good solutions when applied to the correct roof. The use of this solution on non-compatible roofs may not respect the minimum spacing of the module with the roof
Figure 2 – Mini-rail type structures are good solutions when applied to the correct roof. The use of this solution on non-compatible roofs may not respect the minimum spacing of the module with the roof

Technical analysis

Temperature and power relationship

All modules lose power as their cells heat up. This data is described in the data sheet by the power coefficient Pmpp, usually described in percentage of power per degree ºC of cell temperature above the STC test temperature (25 ºC).

Due to its thermal behavior, it is desirable that the module works at the lowest possible temperature. As it is not feasible to install active ventilation systems for the modules, we depend on natural ive ventilation to cool the module. It is then expected that the module installation method will have an effect on its cooling.

The calculation of heat dissipation is complex to be described in a simple equation or to be calculated manually. However, using software it is possible to estimate the loss of generation due to the thermal effect of installing a module with a distance from the roof (recommended by most manufacturers of at least 10 cm) or without any distance at all.

The table and figures below show the results of simulations with the software PVSyst, for a 4,8 kWp residential application with 4 kW inverter in the city of Montes Claros (MG), with and without distancing the modules from the roof.

Figure 3 - Histogram with temperature distribution for the module situation 10 cm from the roof. There is no significant working time above 70 ºC
Figure 3 – Histogram with temperature distribution for the module situation 10 cm from the roof. There is no significant working time above 70 ºC
Figure 4 - Temperature histogram for module close to the roof without air circulation. There is a long period of time above 80 ºC. The distribution is also more displaced towards higher temperature values, thus indicating a greater loss of generation due to the thermal effect.
Figure 4 – Temperature histogram for module close to the roof without air circulation. There is a long period of time above 80 ºC. The distribution is also more displaced towards higher temperature values, thus indicating a greater loss of generation due to the thermal effect

The energy simulation results corroborate the temperature effect seen in the figures above.

Table 1 – Simulation results
Situation Total energy generation Thermal losses – Energy Predicted maximum temperature
With spacing 8121 kWh -8,8% 76 ° C
No spacing 7841 kWh -12% 90 ° C

The maximum temperatures may even be higher than the maximum working temperatures described in the data sheets, thus invalidating the warranty and putting the health of the modules at risk.

Figure 5 - Working temperature specifications of a typical photovoltaic module.
Figure 5 – Working temperature specifications of a typical photovoltaic module.

Temperature of cables, microinverters and accessories

Components close to the modules, such as cables, microinverters, clamps, stickers and conduits that come into or are close to the modules, must normally withstand the same maximum working temperature as the module, as detailed in section 4.3.9 of the NBR 16690 standard.

As seen in item 1) above, the modules can reach up to 90 ºC when mounted very close to the roof. In addition to making access to the cables difficult and increasing the chance of cables breaking during the assembly process, this solution may cause overheating in the components shown, which greatly increases the probability of failure and may invalidate your warranties.

Figure 6 - Working temperature specification of a microinverter. The ambient temperature below a module without space for ventilation can reach the 65 ºC limits of this microinverter.
Figure 6 – Working temperature specification of a microinverter. The ambient temperature below a module without space for ventilation can reach the 65 ºC limits of this microinverter

Fire resistance rating

The modules are tested to have a minimum fire resistance (as detailed in the standard IEC 61730-2). In some parts of the world there is a mandatory minimum level of fire resistance for all building components.

Most manufacturers only guarantee the minimum level of fire protection when all assembly requirements described in the module installation manual are met. It is only possible to guarantee that the module has this fire protection if the recommendations in the product installation manual are met.

Installation and warranty manual analysis

All module manufacturers have installation manuals for their products with instructions and mechanical limits for module assembly. The wind load resistance rating, product durability and fire resistance depend on the correct installation of the module.

Therefore, it is common for module manufacturers to invalidate the product warranty in situations where the module installation did not meet the installation requirements. As an example, the table below shows recommendations from 3 different manufacturers regarding roof spacing.

Table 2 – Analysis of module installation manual for 3 different manufacturers
Manufacturer Original text Translation
“TS” 6.1 MOUNTING METHODS PV

A clearance of at least 115mm(4.5in) (recommended) is provided between the module's frame and the surface of the wall or roof. If other mounting means are employed this may affect the UL Listing or the fire class ratings.

6.1 PV mounting methods

A spacing of at least 115mm must be provided between the module frame and the surface of a wall or roof. If another type of mounting is applied, this may affect the UL fire resistance rating.

"JS" 3.5 Fire Safety

In order to maintain the fire class rating, the distance between the module's frame surface and roof surface shall be at least 10 cm.

5. Mechanical Installation

When the modules are ed parallel to the surface of the building wall or roof, a minimum clearance of 10 cm between the modules frame and the surface of the wall or the roof is required to allow air to circulate behind the modules and to prevent wiring damage .

3.5 Fire safety

For the module to maintain its fire rating, the distance between the module frame and the roof surface must be at least 10 cm.

5. Mechanical Installation

When modules are mounted parallel to the surface of a wall or roof, there must be a minimum spacing of 10 cm between the module frame and the wall or roof surface to allow air age behind the module and to prevent damage to the cabling .

“JK” 2.2.2 Site Selection

When the modules are installed on the roof, they must be separated from the roof by more than 10cm to facilitate air circulation and heat dissipation.

2.2.2 Site selection

When modules are installed on the roof, they must be separated from the roof by more than 10 cm in order to facilitate air circulation and heat dissipation.

Analyzing the manufacturers' warranty , any deviation from the assembly in relation to the installation manual may void the warranty.

Table 3 – Analysis of warranty
Manufacturer Original text Translation
“TS” 4) Exclusions and Limitations

The aforementioned “Limited Warranty” does not apply to any Products which have been subjected to

b) Failure to comply with the requirements of TS manual

  1. Exclusions and limitations

The aforementioned limited warranty do not apply to products that:

b) They do not comply with the TS requirements described in the manual

"JS" 3. Exclusions and Limitations

(b) The Limited Product Warranty and Limited Peak Power Warranty shall not apply to MODULES which have been subject to: Alteration, improper installation or application;

3. Exclusions and limitations

(b) The limited product warranty and peak power warranty do not apply to modules that have been subject to:

Improper alteration, installation or operation

“JK” 7. EXCLUSIONS. This Limited Warranty is subject to the exclusions set forth in this Section 7. The Warranties shall not apply to any Module which has been:\

(g) used in a manner inconsistent with the version of Jinko Installation Manual available on the date the Module is manufactured.

7. Exclusions.

The limited warranty is subject to the exclusion set out in section 7. The warranty does not apply to modules that:

(g) were used in ways inconsistent with the version of the JK installation manual available on the website at the date of product manufacture.

Conclusion

There is no inherently wrong or bad type of structure. There are misapplications. The mistaken application of a structure in a way that is not compatible with the requirement for minimum distance between the module and the roof may result in loss of generation due to the temperature effect and may also result in the loss of the product warranty.

O installer should never ignore the module installation manual, as failure to observe an item may render the manufacturing warranty and potency warranty invalid.

Photo by Mateus Vinturini
Mateus Vinturini
Specialist in photovoltaic systems and electrical engineer graduated from UNICAMP (State University of Campinas). Science and technology enthusiast, with experience in the field of solar energy, both commercially and in the design, dimensioning and installation of photovoltaic systems. 

Answers of 10

  1. I have noticed that the distance between the roof and solar s varies depending on the type of roof, zinc approximately 5 cm and ceramic approximately 10 cm…
    Is it possible to increase the distance, say 20 ~ 30 cm or more, guaranteeing the performance of the plates and without compromising the safety of the s (increasing the number of and more resistant fasteners) in relation to unusual winds that could make the s fly away?

    1. Good afternoon, Mario, how are you? Firstly, in every project it is ideal that you carry out a study on the wind isopleths of the location where the project will be installed, to know which structure to use, and on the distance from the module. that he must be

  2. Thank you very much for sharing this information. Since the temperature in a photovoltaic is very closely related to the conversion yield, I believe that we also need to explore the minimum distance “between” s, to facilitate the natural convection of ventilation air. Normally, we see strings with s practically glued together. The ones located higher on the roof receive the hot air heated by the s mounted lower down. Leaving gaps “between” s to facilitate the exit of hot air and increase the flow of natural convection can be a good solution, when the roof has physical space. They also allow access to facilitate cleaning. So far I have not been able to find any reference on this subject. Here is a suggestion for investigation. Thank you.

  3. My plant was assembled correctly in 2019, complying with the minimum limit of 10 cm of the tile, but in 2021, with the roof facing North to improve the system's generation capacity, the integrator lowered it to zero, since the roof is made of thermal tile, which he said was safer against strong winds. However, after the installation, I became concerned about the fact that the s were so close to the tiles, and that's when I started researching the subject and found articles that say when there is a minimum ventilation space, so I hired a new technician and redid the arrangement again, respecting the minimum space of 10 centimeters. I would like to report the lack of information on the part of the integrators, which caused double damage. "FIRST, by not asking about roof positions, SECOND, by applying them outside the manufacturer's standards.

  4. Good morning. The issue is delicate, however, not only the installer has this responsibility for correct positioning of the installation. Demand in the market grows every day and there are several companies testing new structures. I understand, however, that this responsibility for correct distancing lies with the company that supplies the solar kit and not the installer. As an installer, I always use the material that is given to me when I decide on the type of roof.

  5. There are many companies using the mini rail without the , on metal roofs, I believe it will cause damage to the modules.

Leave a comment

Your email address will not be published. Required fields are marked with *

Comments should be respectful and contribute to a healthy debate. Offensive comments may be removed. The opinions expressed here are those of the authors and do not necessarily reflect the views of the author. Canal Solar.

Receive the latest news

Subscribe to our weekly newsletter

<
<
Canal Solar
Privacy

This website uses cookies so that we can provide you with the best experience possible. Cookie information is stored in your browser and performs functions such as recognizing you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.